DMO1-201 WEB BASED DATA LOGGER With Control Function

The DAN DM01 is the basic monitoring system in the DAN range. It is installed in the field either as a land based or buoy based system. Configuration of the DM01 is accomplished by logging into the DAN website and entering the relevant information into the account pages. Note that the account is protected by a group name, user ID and password specific to each user and product.


The DM01 has 6 general purpose analogue inputs and one counter input. Each of the general purpose inputs are switch selectable to suite most industrial grade probes. Should probes need power supplied from the DM01 unit, separate power boards are available for this purpose. Battery voltage can be monitored if required.

The DM01 has a digital input suitable for counting pulses. The unit will capture all pulses up to a frequency of 4kHz.The DM01 has two software alarm points associated with each of its inputs. There are 3 relays incorporated to provide local control and alarm action. The relays can be associated with any input or combination of inputs.

The DM01 has on board batteries which will allow it typically to operate for 24 to 72 hours without external power. This time is dependant upon the type of transducers connected to the inputs and the duty cycle of the unit. If a dc supply is available at the site, the unit may be recharged by any available source of dc voltage in the range 10 to 50V. If mains power is available, a plug pack with an output in this range can be connected as the means of recharging the batteries. If no power source is available then solar cells can be directly connected and used as the means of recharging the batteries. DAN can supply solar cells and plug packs as part of the implemented solution.

The DM01 has an inbuilt GSM/GPRS modem that is used to communicate both data and control signals between the DM01 and the web server via the internet gateway provided by the mobile phone service provider. An option to use CDMA is also available at additional cost.Data is available by logging onto the DAN web site using password and logon ID. Full access to all the relevant information necessary to set up and run the unit is available. Total control of how much or how little information is displayed on the website can be managed. Data available includes data from the site, alarm messages generated and a log of all changes made to the system including details of the logon ID that made the change.The web site also provides facilities to set local control or alarm parameters, manage passwords and access permissions, input telephone numbers and email addresses for alarm notification and calibration of the inputs.Instantaneous data may be obtained form the unit by calling the unit from one of the authorised numbers noted into the web site by the user.

Inputs:
Type 6 X Analogue
1 X Counter
(Analogue inputs support 2 or 3 wire RTD)
Input Ranges: Dip switch selectable:
Current Range 0 – 20mA/4 – 20mA
Voltage Range 1 0 – 10V (0 - 5V & 1 – 5V)
Voltage Range 2 0 – 4V
RTD Range Pt100 span -15oC to 120oC
   
Input Ranges:  
Accumulator Use input 1 As An Accumulator
(This requires the counter to be set to seconds counting)
Internal Battery Monitoring Use input 5 to monitor internal battery voltage.
Digital Inputs Use analogue inputs as digital inputs
Input Set-Up All User Specified Via The Dan Web Site
Resolution 10 Bit (>0.1%)
Sampling Rate 19/Second
Digital Pulse Input Rate 0 – 4kHz
Output:
Relay Outputs 3 x SPST N.O. relays with contacts rated 24Vdc @ 5A
Field Hardware:
Real time clock Included
Internal battery back-up 2 x 12V sealed lead acid
Charging options 10 to 50V by power pack or solar direct connect facility
Housing IP65
Housing dimensions 180 x 254 x 111 deep
Weight 3.5Kg
Operating Conditions:
Operating Temperature -10oC to +60oC
Relative Humidity 0 – 90% RH non-condensing
Temperature Stability <0.01% of span/oC
Long Term Stability <0.1% of span/10,000 Hrs
Power Conservation May be enabled when solar power used
Web Based Software:
Input Alarm/Control Variable set points/time profiling
Points Variable dead band
Variable delay
2 Alarms per input
SMS option for alarm & reset with user scripted message
Note: Battery conservation mode available if input 5 used for monitoring battery voltage
Set-up/Change Data Reporting Set/change variables for any given input
Data Report Format Max, min average for reporting period
Instantaneous Data Logged when requested and available on search
Changes Log All changes made are recorded and available for search
Web Retention of Data Retained for 90 days available in tabulated or graphical form
Access Security Multi level access and data view options – user set
Session Time-out Settable by user
Grouping Units may be grouped for easy log-on
Relay Activation May be linked to alarm/control points
Calibration Set from Web Site
Communications:
Modem Type GPRS/GSM approved modem included
Communication Method TCP/IP
Period Data Sent Date & time stamped, maximum, minimum & average for period
On Site Software:
Alarm Recognition Immediate for alarms based on input data
Reporting Period Standard variable from 60 mins.
(More frequent at additional cost down to 5 Min)
Remote Reset Enabled by specified phone contact
Data Accumulation Up to 200 blocks non reported
Instantaneous Data Enabled by specified phone contact
IMPORTANT NOTICE:
Due to continued product development , specifications may change without notice. Always refer to Data Acquisition Networks for the latest information.